Performance Specifications
Parameter |
4 Channel | ||
Mux |
Demux | ||
Channel Wavelength (nm) |
1270~1610 | ||
Center wavelength Accuracy (nm) |
±0.5 | ||
Channel Spacing (nm) |
20 | ||
Channel Passband (@-0.5dB bandwidth (nm) |
>13 | ||
Insertion Loss (dB) |
≤1.7 | ||
Channel Ripple (dB) |
0.3 | ||
Isolation (dB) |
Adjacent |
>30 | |
Non-adjacent |
>40 | ||
Inertion Loss Temperature Sensitivity (dB/℃) |
<0.005 | ||
Wavelength Temperature Shifting (nm/℃) |
<0.002 | ||
Polarization Dependent Loss (dB) |
<0.1 | ||
Polarization Mode Dispersion |
<0.1 | ||
Directivity (dB) |
>50 | ||
Return Loss (dB) |
>45 | ||
Maximum Power Handling (mW) |
300 | ||
Opterating Temperature (℃) |
-5~+75 | ||
Storage Temperature (℃) |
-40~85 | ||
Package dimension (mm) |
L100 x W80 x H10 |
L140 x W115 x H18 |
Above specification are for device without connector.
Ordering Information
CWDM |
X |
XX |
X |
XX |
X |
X |
XX |
|
Channel Spacing |
Number of Channels |
Configuration |
1st Channel |
Fiber Type |
Fiber Length |
In/Out Connector |
C=CWDM Grid |
02=2 Channel |
M=Mux D=Demux O=OADM |
27=1270nm …… 47=1470nm 49=1490nm …… 61=1610nm SS=special |
1=Bare fiber 2=900um loose tube 3= 4= |
1= 2= S=Specify |
0=None 1=FC/APC 2=FC/PC 3=SC/APC 4=SC/PC 5=ST 6=LC S=Specify |